Strany 1 - Ag Leader PN 4002083 Rev. L

Operator ManualFirmware Version 5.2Ag Leader PN 4002083 Rev. L

Strany 2

x Firmware Version 5.2Down ForceModes of Operation ... 18

Strany 3 - Table of Contents

84 Firmware Version 5.2The Auxiliary Input Diagnostics screen lists the active switches. These color-coded boxes display the following diagnostics:

Strany 4 - Field Operations

85 SETUPSETTINGS• Outside Boundary OptionSelect one of the two options to determine system behavior when a section exits a field boundary.• Coverag

Strany 5 - External Drive

86 Firmware Version 5.2• Measure and enter the vertical height of the antenna above the ground.Note: Accuracy when measuring for a specific settin

Strany 6 - AgFiniti

87 SETUPSETTINGSSection Offsets• Press the first to enter the distance from the mid-point of the swath section to the machine’s centerline. Select

Strany 7 - Guidance

88 Firmware Version 5.2

Strany 8 - OnTrac2+

89 SETUPVIRTUAL TERMINALSETUPVIRTUAL TERMINALThe display is compatible with the ISO 11783 (ISOBUS) Virtual Terminal Standard. This enables support

Strany 9 - Planting

90 Firmware Version 5.2Once a Virtual Terminal has been enabled will appear in the task bar. Toggle between the Virtual Terminal run screen and o

Strany 10 - KINZE Planter Monitor Module

91 SETUPVIRTUAL TERMINALIf there are multiple ISO implements connected, press the VT button to toggle between Working Sets.The Working Sets can a

Strany 11 - Application

92 Firmware Version 5.2Assign implement functions to ISO compatible inputs.The number of functions and inputs shown on the Auxiliary Mappings scree

Strany 12 - Injection

93 SETUPVIRTUAL TERMINAL Pressing the Diagnostics button on the Devices screen brings up the ISO Node Diagnostics screen which shows the following

Strany 13 - Strip Till

xi TABLE OF CONTENTSTroubleshooting...213Alarms on

Strany 14 - Harvest Monitoring/Mapping

94 Firmware Version 5.2Select the controller make and modelThe rest of the steps will follow the Liquid Rate Controller Configuration.ISOBUS SETTIN

Strany 15 - Appendix

95 SETUPVIRTUAL TERMINALRead in object poolSet up configuration in Virtual TerminalLoad configuration on display’s map screen.

Strany 16

96 Firmware Version 5.2

Strany 17 - ABOUT THIS MANUAL

97 SETUPAGFINITISETUPAGFINITICONNECTING TO WI-FI NETWORKInsert USB Wi-Fi Adapter to USB port of the display.To connect to a Wi-Fi network:Press: Ho

Strany 18 - SYSTEM FEATURES

98 Firmware Version 5.2One or more networks are in range but display is not configured to connect to a network.Connected to network. Green bars rep

Strany 19 - TECHNICAL SPECIFICATIONS

99 SETUPAGFINITIFILE TRANSFERFile Transfer requires a File Transfer license (one per display). AgFiniti is compatible with Ag Leader Integra and Ve

Strany 20 - CAUTIONS AND WARNINGS

100 Firmware Version 5.2The Downloaded tab shows files that are stored on the internal memory of the display. These files can be accessed when ther

Strany 21 - VIEWING THIS MANUAL ONLINE

101 SETUPAGFINITIIMPORTING A PRESCRIPTION

Strany 22 - 6 Firmware Version 5.2

102 Firmware Version 5.2IMPORTING A VARIETY REFERENCE MAP (HARVEST ONLY)from Options screen in the Event WizardPress the “Select Event” button and

Strany 23 - INSTALLATION

103 SETUPAGFINITIAllows remote viewer to view display screens without display user having to give permissionPress: Home button > AgFiniti button

Strany 24

xii Firmware Version 5.2Liquid PWM Control Valve Settings Description... 242Dickey-John NH3 Conversions..

Strany 25 - SCREEN ICON CONVENTIONS

104 Firmware Version 5.2

Strany 26 - March 2015

105 GPS GPSGPSGPS BUTTONDuring your field operation, the GPS (satellite) button in the upper left-hand side of the Status Bar should appear as gree

Strany 27

106 Firmware Version 5.2• Note: If using OmniSTAR, see “OmniSTAR Settings” on page 107.• Differential SourceSelect choice of WAAS/EGNOS, Satellite

Strany 28 - LOCATION SPECIFIC SETUP

107 GPSOMNISTAR SETTINGSOmniSTAR (Differential Source drop-down menu)Press: Home button > Setup (wrench) button > GPS button > Receiver Se

Strany 29 - SINGLE DISPLAY

108 Firmware Version 5.2• FrequencyIn the Frequency drop-down list box, select the geographic region where you are located. If you wish to enter a

Strany 30 - File Selection

109 GPSNote: The use of OmniSTAR® differential requires purchase of a subscription from OmniSTAR. Settings related to using satellite differential

Strany 31

110 Firmware Version 5.2The Serial Port Settings screen is the place where you can adjust GPS output. The appearance of the Serial Port Settings sc

Strany 32

111 GPS- ASAP represents a Hz value of more than 1.• NMEA MessagesThese checkboxes represent various communication protocols or formats that have b

Strany 33 - IMPORT SETUP DATA

112 Firmware Version 5.2• GPS Speed• Position RateThe frequency that the receiver is sending the display your position in longitude and latitude (G

Strany 34 - HOME SCREEN

113 GPS• Correction AgeThe length of time since the GPS receiver has obtained its last update.Note: The age of the DGPS corrections (as delivered

Strany 35 - SETUP BUTTONS

xiii TABLE OF CONTENTS Europe Settings ...260Sensor Setup...

Strany 36 - DISPLAY BUTTON

114 Firmware Version 5.2• Receiver ID• Firmware Version• Serial Number• e-Dif Subscription• GLONASSGPS INFORMATION - OMNISTAR TABPress: GPS (satell

Strany 37 - DISPLAY TAB

115 GPSGPS INFORMATION - NTRIP or Press: GPS (satellite) button > GeoSteer tab or ParaDyme• NTRIP ConnectConnects the display to the NTRIP corre

Strany 38 - FEATURES TAB

116 Firmware Version 5.22500 RTK SETUPPress: Home button > Setup (wrench) button > GPS button > Receiver Setup (wrench) button• Differenti

Strany 39 - ADVANCED TAB

117 GUIDANCE GUIDANCEGUIDANCEGUIDANCE/STEERING CONTROLSETUPPress: Home button > Setup (wrench) button > GPS button • Manual GuidanceSelect th

Strany 40 - CONFIGURATION BUTTON

118 Firmware Version 5.2LIGHTBAR SETTINGSSETUPPress: Home button > Setup (wrench) button > GPS button > Lightbar Settings button• LED Spac

Strany 41 - PRODUCT TAB

119 GUIDANCENEW PATTERNSTRAIGHTSelect PatternPress: Map button > Guidance tab (in Mapping Toolbox) > New Pattern button > Straight Pattern

Strany 42 - Application Settings

120 Firmware Version 5.2Patterns are automatically saved when the B point is set (A point for A+ pattern). For more information see “AutoSave” on p

Strany 43 - Grain Harvest Settings

121 GUIDANCE• Press to mark point B. The AB line appears on the map screen and point B is marked with a red ball.Note: Guidance extends beyond t

Strany 44 - 28 Firmware Version 5.2

122 Firmware Version 5.2Press: Map button > Guidance tab (in Mapping Toolbox) > New Pattern button > Identical Curve Pattern SelectionSyst

Strany 45 - MANAGEMENT SETUP

123 GUIDANCESelect PatternPress: Map button > Guidance tab (in Mapping Toolbox) > New Pattern button > Pivot Pattern SelectionSystem defau

Strany 46 - Some Modules Not Detected

xiv Firmware Version 5.2Controller Settings... 294Strip Till

Strany 47 - View Summary

124 Firmware Version 5.2• Shift By DistanceThis sets the field edge as the distance and direction in relation to the AB Line created. In the Pivot

Strany 48 - Enable Management

125 GUIDANCEPress . You will automatically return to the Map screen.Inputting Paths into SmartPathAB ManagerPress: Map button > Guidance tab (in

Strany 49 - Field: Orab

126 Firmware Version 5.2 As you continue using the SmartPath, the map screen will display three lines:• (A) The Base Path Appears as a black line,

Strany 50

127 GUIDANCETo adjust this setting, press the Guidance Options button on the Guidance Tab. The Guidance Options screen appears. Press the Smart Tab

Strany 51 - Farm and Field

128 Firmware Version 5.2MANAGE PATTERNSSPATIAL SORTPress: Map button > Guidance tab (in Mapping Toolbox) > New Pattern buttonSpatial Sort all

Strany 52 - Field Information

129 GUIDANCEREMOVE PATTERN/REMOVE ALL PATTERNSTo remove a pattern from the display memory, first press the Manage Patterns button on the Guidance T

Strany 53 - SEASON TAB

130 Firmware Version 5.2The Pattern Cycle Button allows the user to easily cycle between patterns with a single button press. Patterns will cycle i

Strany 54 - USERS TAB

131 GUIDANCEPAUSEPress: Map button > Guidance tab (in Mapping Toolbox) > Setup (wrench) button > Pause buttonThe Pause button allows your

Strany 55 - PERMISSIONS

132 Firmware Version 5.2 Nudge allows you to adjust the swaths by a specified distance.Small Nudge (single arrow) shown on left.Large Nudge settin

Strany 56 - ERMISSION LEVEL FOR OPERATORS

133 GUIDANCEShift moves all of the swaths by a specified distance to the left or right, (including the AB line). The swaths can be shifted by a dis

Strany 57 - Custom Permission

xv TABLE OF CONTENTSAutomatic Variety Tracking ...317Automatic Region Changing...

Strany 58 - - SmartPath

134 Firmware Version 5.2Motor Aggressiveness — determines how aggressively the motor engages.Heading Aggressiveness — determines how aggressively t

Strany 59 - FORGOTTEN PASSWORDS

135 GUIDANCE• Paths Between Tramlines - use to enter the number of passes between tramlines.• Paths to Start Field - use to enter the number of

Strany 60 - BUSINESSES TAB

136 Firmware Version 5.2

Strany 61

137 GUIDANCEONTRAC2+GUIDANCEONTRAC2+To ensure proper AutoSteer Operation make sure your GPS source is setup properly.Complete the following steps t

Strany 62 - 46 Firmware Version 5.2

138 Firmware Version 5.2To return to the previous screen, press the Back icon. Press the Back icon from the AutoSteer Setup screen to return to you

Strany 63 - FIELD OPERATIONS

139 GUIDANCEONTRAC2+The Control Point of a vehicle is defined as:• Standard Wheeled Vehicle (MFWD, Floater, Sprayer) - Rear Axle• Track Vehicle - C

Strany 64 - CONFIGURATION SETUP SCREEN

140 Firmware Version 5.2EDITSelect VehiclePress: Vehicle button > Manage Vehicle button > Select Vehicle > Edit buttonSelect the vehicle f

Strany 65 - SETUP EVENT

141 GUIDANCEONTRAC2+Export profile to a USB drive1. Insert a USB drive into the display.2. Select the vehicle you want to export, and press Expor

Strany 66 - <1>

142 Firmware Version 5.2• OnTrac2 ECU Tilt Zero Measurements 1 and 2: The ECU has a tilt sensor in it to help take into account side hills and bump

Strany 67 - RUN SCREENS

143 GUIDANCEONTRAC2+5. When the vehicle's draw bar reaches the flag, stop the vehicle, place it in park, turn off the AutoSteer system, and e

Strany 68

xvi Firmware Version 5.2

Strany 69 - GPS SIGNAL INDICATOR

144 Firmware Version 5.2STEERING COMPONENTSPress: Vehicle button > Steering ComponentsThis screen enables you to adjust steering components. The

Strany 70 - MAPPING TOOLBOX

145 GUIDANCEONTRAC2+3. Use the Steering Command buttons to send the various commands to the MDU. Observe that the steering wheel behaves according

Strany 71 - Map Legend tab

146 Firmware Version 5.2MANAGE SETTINGSPress: System button > Manage Settings buttonThe Manage Settings screen enables you to:• Save or delete t

Strany 72 - - Rainbow

147 GUIDANCEONTRAC2+DatabaseThe database contains all the vehicle and system parameter data required for system operation. A backup of the database

Strany 73 - Topography

148 Firmware Version 5.2The Accessories menu is used to activate or deactivate optional sensors. Currently only the remote engaged switch is availa

Strany 74

149 GUIDANCEONTRAC2+• GPS Mode parameter — current GPS mode of the receiver.• PDOP (Positional Dilution of Precision) — measure of the strength of

Strany 75 - HEADLANDS

150 Firmware Version 5.2

Strany 76 - Add a Headland

151 TILLAGETILLAGETILLAGECREATE TILLAGE CONFIGURATIONPress: Home button > Setup (wrench) button > Configuration (tractor) button > Configu

Strany 77 - Load Headlands

152 Firmware Version 5.2The Configuration Setup screen appears. The appearance of this screen will vary depending upon your particular operating co

Strany 78 - Headland Alarm Settings

153 TILLAGE • (A) GPS Status• (B) Total Field Acres• (C) Ground Speed• (D) Diagnostics button• (E) Map Legend• (F) Logging Status button• (G) AutoS

Strany 79

1 GENERALABOUT THIS MANUALGENERALGENERALABOUT THIS MANUALINTRODUCTION AND COMPANY PROFILEABOUT USWelcome to the Ag Leader Technology family. Ag Lea

Strany 80

154 Firmware Version 5.2

Strany 81

155 PLANTINGCREATE PLANTING CONFIGURATIONPLANTINGPLANTINGCREATE PLANTING CONFIGURATIONMost of the functionality of the display is not available unt

Strany 82

156 Firmware Version 5.2• Split Rows EnabledCheck this box to enable the display to log data from the planter’s Split Row units. (For split row-ena

Strany 83 - SUMMARY REPORT

157 PLANTINGCREATE PLANTING CONFIGURATIONYou will now be returned to the Operation Configuration Wizard.14. Select ImplementSelect Implement from

Strany 84 - SMART REPORT™

158 Firmware Version 5.2

Strany 85

159 PLANTINGAUTOSWATHPLANTINGAUTOSWATHROW SHUTOFFCreate an Implement configuration with Row Shutoff by following the procedure in “Create Planting

Strany 86 - ONTROL CHANNEL REPORT CONTENT

160 Firmware Version 5.2AUTOMATIC AUTOSWATH CONTROLPress: Home button > Setup (wrench) button > Configuration (tractor) button > Configura

Strany 87 - VIEW MAP

161 PLANTINGAUTOSWATHCHECKING AUTOSWATH PERFORMANCE FOR ROW SHUTOFFThe settings given in the above AutoSwath look-ahead table shown previously have

Strany 88 - 72 Firmware Version 5.2

162 Firmware Version 5.2Result — The AutoSwath anticipates headlands sooner and turns the planter on sooner.

Strany 89 - EXTERNAL DRIVE

163 PLANTINGRATE CONTROLPLANTINGRATE CONTROLHYDRAULIC SEED RATE CONTROLThe Hydraulic Seed Control Module allows operators to control up to three hy

Strany 90 - EXPORT FILES

2 Firmware Version 5.2ph: (515) 232-5363fax: (515) 232-3595e-mail: [email protected]: This display has an internal lithium coin cell batt

Strany 91 - MANAGE FILES

164 Firmware Version 5.2Channel Tab settings• Gear RatioRatio of the revolutions of the hydraulic drive as compared to one revolution of the seed m

Strany 92 - 76 Firmware Version 5.2

165 PLANTINGRATE CONTROLControl Valve Settings - Servo• Valve Response 1Determines the speed of the servo valve when product control error exceeds

Strany 93 - DEVICE INFORMATION

166 Firmware Version 5.2HYDRAULIC SEED CONTROLLER SETTINGS FOR SPECIFIC PLANTERSNote: The settings, provided below, should be a good starting poin

Strany 94 - 78 Firmware Version 5.2

167 PLANTINGRATE CONTROLHYDRAULIC SEED METER CALIBRATION NUMBERSPrior to calibrating the Hydraulic Seed Meter, the numbers that appear in the Meter

Strany 95 - SETTINGS

168 Firmware Version 5.2STEPPER SEED RATE CONTROLThe Stepper Seed Control module allows Rawson ACCU-RATE Variable Rate Controller to control up to

Strany 96 - SPEED INPUT SETTINGS

169 PLANTINGRATE CONTROLChannel Tabs• Max Meter SpeedThis number represents the maximum recommended RPM of the seed meter, and is specified by the

Strany 97 - CALIBRATE DISTANCE

170 Firmware Version 5.2GEAR RATIO CALCULATIONS FOR SEED RATE MOTORSThe Gear Ratio is a setting that appears on the Controller Tab for the Stepper

Strany 98 - AUXILIARY INPUT

171 PLANTINGRATE CONTROLGear Ratio Drawing - For Multiple Drive Combinations Seed Rate Drive Setting (Calculating a Gear Ration for Multiple Dri

Strany 99

172 Firmware Version 5.2Gear Ratio Drawing Shaft DrivesSeed Rate Drive Setting. Carry the Decimal place to the nearest 0.001 for accurate resul

Strany 100 - Configuration

173 PLANTINGRATE CONTROLSeed Ratio Calculation Example Procedure for Shaft DrivesThis example assumes a single drive motor. Step 5 notes that this

Strany 101 - VEHICLE OFFSETS

3 GENERALABOUT THIS MANUAL• 28-pin auxiliary connection• RAM mountUSB FLASH DRIVEDisplay kits include a USB Flash Drive which you can use to save a

Strany 102 - Select Your Specific

174 Firmware Version 5.2Press: Map button > Meter RPM button > Planter Drives > Prime Seed Meter buttonA message displays, stating “Seed M

Strany 103 - ADVANCED SECTION OFFSETS

175 PLANTINGRATE CONTROL7. Seed Dispensing CompleteWhen the meter is finished dispensing seed, the button will change back to its original green c

Strany 104 - 88 Firmware Version 5.2

176 Firmware Version 5.2• (B) Target Rate• (C) Actual RateTwo items, Target Rate and Actual Rate, appear on each Product Tab shown in the Product C

Strany 105 - VIRTUAL TERMINAL

177 PLANTINGRATE CONTROLThe Rate Control Settings screen appears.• The top drop-down menu selects a specific variety for rate control. This drop-do

Strany 106 - ISOBUS Settings

178 Firmware Version 5.21. Press the Rx button to show a legend of the prescription rate.2. After pressing the Rx button, the prescription rate a

Strany 107 - AUXILIARY ASSIGNMENT

179 PLANTINGRATE CONTROLb. From the Run screen, open the product application rate window, and highlight the appropriate product. Select Manual cont

Strany 108 - Low fan speed detected

180 Firmware Version 5.2Error Message: “Meter Not Moving - Drive #”Possible Cause: Either the Seed Meter Calibration failed, or the Seed Meter Pri

Strany 109 - CONFIGURATION SETUP

181 PLANTINGDOWN FORCEPLANTINGDOWN FORCEThe gauge wheel sensors measure the weight carried by the gauge wheels. The system uses this information to

Strany 110 - ISOBUS SETTINGS

182 Firmware Version 5.2At the Down Force Options screen, the operator can choose a Down Force configuration from the drop down menu:The rows liste

Strany 111

183 PLANTINGDOWN FORCEHydraulic Pressure to Down Force Conversion adjusts system to accurately display changes to hydraulic down force. This settin

Strany 112 - 96 Firmware Version 5.2

Firmware Version 5.2© 2014 Ag Leader Technology2202 South Riverside DriveAmes, Iowa 50010 USAAll Rights Reserved

Strany 113 - AGFINITI

4 Firmware Version 5.2SYSTEM AND UPGRADESAg Leader Technology will periodically provide operating program updates that will improve the performance

Strany 114 - CONNECTING TO AGFINITI

184 Firmware Version 5.2PWM FrequencyThe frequency that the PWM control valve is pulsed at should be set to 200.Calibrate Pressure Sensor (Grayed o

Strany 115 - FILE TRANSFER

185 PLANTINGDOWN FORCEDown Force is not shown when in Monitor Only mode.PLANTER OPTIONS SCREENPress: Map button > Settings button > Down Forc

Strany 116 - EXPORT SETTINGS

186 Firmware Version 5.2PLANTER PERFORMANCE SCREEN Press: Planter Performance button on the Map screen to go to the Advance Seed Monitoring screen.

Strany 117 - IMPORTING A PRESCRIPTION

187 PLANTINGDOWN FORCEDown Force InadequateSystem hydraulic pressure is at maximum pressuredown force system does not achieve acceptable gauge whee

Strany 118 - Select Event

188 Firmware Version 5.2

Strany 119

189 PLANTINGSEED TUBE MONITOR MODULEPLANTINGSEED TUBE MONITOR MODULECONFIGURATION SETUPPress: Home button > Setup (wrench) button > Configura

Strany 120 - 104 Firmware Version 5.2

190 Firmware Version 5.2SEED MONITOR SETUPPress: Home button > Setup (wrench) button > Configuration (tractor) button > Configuration tab

Strany 121 - GPS SETTINGS

191 PLANTINGSEED TUBE MONITOR MODULESEED TUBE SENSOR CONFIGURATIONPress: Home button > Setup (wrench) button > Configuration (tractor) button

Strany 122 - GPS Settings

192 Firmware Version 5.2PLANTER OPTIONSPress: Map button > Settings button > Seed Monitor taborPress: Advanced Seed Monitoring button > Se

Strany 123 - OMNISTAR SETTINGS

193 PLANTINGSEED TUBE MONITOR MODULESEED MONITOR DIAGNOSTICSPress: Map button > Settings button > Seed Monitor tab > Diagnostics buttonThe

Strany 124 - MNISTAR SETTINGS — GPS 2500

5 GENERALABOUT THIS MANUALCROSS-REFERENCES AND WEB LINKSThroughout this manual, numerous cross-references are provided to other pages or sections.

Strany 125 - SERIAL PORT SETTINGS

194 Firmware Version 5.2SEED MONITOR THRESHOLDSPress: Map button > Settings button > Seed Monitor tab > Thresholds buttonAdjust Seed Tube

Strany 126 - - The default rate is 1 Hz

195 PLANTINGSEED TUBE MONITOR MODULE• (F) Seed Tube Monitor bar graphBars represent row units. Each bar’s row height represents that row’s populati

Strany 127 - NFORMATION

196 Firmware Version 5.2PLANTING MAP SCREEN - ZOOM DETAIL • (A) GPS Status• (B) Total Field Acres• (C) On-screen Lightbar• (D) Ground Speed• (E) D

Strany 128

197 PLANTINGSEED TUBE MONITOR MODULELegend SetupTo change the colors of the varieties that appear on the Run screen map, press the Varieties button

Strany 129 - NFORMATION - RECEIVER TAB

198 Firmware Version 5.2ADVANCED SEED MONITORINGBAR GRAPHTapping subsequently will toggle the bar graph between all the following seed placement pe

Strany 130 - NFORMATION - OMNISTAR TAB

199 PLANTINGSEED TUBE MONITOR MODULEPLANTER PERFORMANCE SCREEN• (A) All Rows• (B) Hydraulic Drive• (C) Bar Graph• (D) Population• (E) Spacing Quali

Strany 131 - GPS INFORMATION FOR 2500 RTK

200 Firmware Version 5.2• (F) SingulationDisplays the average Singulation for the planter, or selected sections of the planter, along with the high

Strany 132 - 2500 RTK SETUP

201 PLANTINGSEED TUBE MONITOR MODULEVIRTUAL SEED TRENCHThe virtual seed trench shows the placement of each seed of a problematic row to help determ

Strany 133 - GUIDANCE

202 Firmware Version 5.2

Strany 134 - LIGHTBAR SETTINGS

203 PLANTINGKINZE PLANTER MONITOR MODULEPLANTINGKINZE PLANTER MONITOR MODULEThe KINZE Planter Monitor Module is a feature that displays planting da

Strany 135 - NEW PATTERN

6 Firmware Version 5.2

Strany 136 - ADAPTIVE CURVE

204 Firmware Version 5.2• Front Units and Rear UnitsUse / to adjust the number of front and rear planting units, if necessary.• Shaft RPM SensorsUs

Strany 137 - IDENTICAL CURVE

205 PLANTINGKINZE PLANTER MONITOR MODULE• EdgeVac SensorsUse / to enter the number of EdgeVac® sensors on the planter. Calibrate EdgeVac sensors on

Strany 138 - Create AB line using 2 points

206 Firmware Version 5.21. To start the Sensor Muxbus Detection process, make any settings changes necessary at the Planter Configuration screen a

Strany 139 - Select Pattern

207 PLANTINGKINZE PLANTER MONITOR MODULE5. Resolve Any Possible ErrorsWhen the Muxbus Detection Process begins, each row unit will display “N/A” (

Strany 140 - SMARTPATH

208 Firmware Version 5.2KINZE Seed Monitor AlarmsPress: Home button > Setup (wrench) button > Configuration (tractor) button > Configurati

Strany 141 - Cycle between Loaded Paths

209 PLANTINGKINZE PLANTER MONITOR MODULE2. Drive from start to end pointsPosition the vehicle at the start marker. Press the green-colored Start b

Strany 142 - SmartPath Guidance Options

210 Firmware Version 5.2Press: Advanced Seed Monitoring button > Setup (wrench) button > Planter Monitor tabMake changes to the bar graph’s r

Strany 143

211 PLANTINGKINZE PLANTER MONITOR MODULEKINZE DISPLAY ITEMS ON EQUIPMENT TABThe left-hand side of the Map screen’s Equipment Tab includes a number

Strany 144 - SPATIAL SORT

212 Firmware Version 5.2 Shown is an example of a KINZE Planter Monitor Module (PMM) with Row Shutoff and three Hydraulic Seed Control drives.• (A)

Strany 145 - PATTERN GROUPS

213 PLANTINGKINZE PLANTER MONITOR MODULE• Shaft SpeedThe speed of the planter drive shafts, in RPM.• Tank WeightThe weight of seed in each tank of

Strany 146 - GUIDANCE OPTIONS

7 GENERALINSTALLATIONGENERALINSTALLATIONDISPLAY HARDWARE • (A) USB media slotUsed for data transfer in and out of the display.• (B) speakerThe bui

Strany 147 - REMARK A

214 Firmware Version 5.2Error Message: “(Row #) mux bus data line short to mux bus ground”.Possible Cause: Population sensor’s mux bus signal wire

Strany 148 - Remark A

215 PLANTINGKINZE PLANTER MONITOR MODULESolution: Check tractor’s electrical system.Error Message: “(Row #) Seed Rate Alarm”.Possible Cause: The

Strany 149 - ONTRAC TUNING

216 Firmware Version 5.2

Strany 150 - TRAMLINES

217 APPLICATIONLIQUID RATE CONTROLAPPLICATIONAPPLICATIONLIQUID RATE CONTROLDirectCommand allows the variable rate application of single or multiple

Strany 151

218 Firmware Version 5.2Once container has been configured press to continue.10. Enter Swath WidthPress to enter swath width.11. Enter Number

Strany 152 - 136 Firmware Version 5.2

219 APPLICATIONLIQUID RATE CONTROL17. Select Implement.Press to continue.18. Select Second Implement.Use drop-down menu to select Implement or

Strany 153 - ONTRAC2+

220 Firmware Version 5.2Tank Mix SetupA tank mix can contain up to seven individual components.1. Select Tank Mix from the list box and press to

Strany 154 - SETUP WIZARD

221 APPLICATIONLIQUID RATE CONTROL• Speed Input SetupFor more information, see “Speed Input Settings” on page 80.• Calibrate DistanceFor more infor

Strany 155 - MANAGE VEHICLE

222 Firmware Version 5.2The Controller Settings screen appears. Make the following adjustments:• Flow Meter CalibrationCalibration value representi

Strany 156 - EXPORT/IMPORT

223 APPLICATIONLIQUID RATE CONTROLControl Valve Settings - PWM• PWM FrequencyThe frequency that the PWM control valve is pulsed at. Settings can be

Strany 157 - AUTO CALIBRATE

8 Firmware Version 5.2Mount the display to a secure support inside the vehicle cab. The following must be considered when choosing a mounting locat

Strany 158 - Adjust Lateral Offset

224 Firmware Version 5.2• Response ThresholdDetermines where the control channel switches between using Valve Response 1 and Valve Response 2 speed

Strany 159 - STEERING ADJUST

225 APPLICATIONLIQUID RATE CONTROLAfter specifying Fence Row Nozzle settings at the Auxiliary Input Assignment screen, the Fence Row Nozzle Indicat

Strany 160 - STEERING COMPONENTS

226 Firmware Version 5.2APPLICATION MAP SCREEN - ZOOM TO DETAIL• (A) GPS Status• (B) Ground Covered• (C) Ground Speed• (D) Diagnostics button• (E)

Strany 161 - SYSTEM MENU

227 APPLICATIONLIQUID RATE CONTROLRATE CONTROL: PRODUCT CONTROL TOOLBOXDuring DirectCommand Run Time operations, the Product Tabs are shown in the

Strany 162 - MANAGE SETTINGS

228 Firmware Version 5.2• Rate Increase and Decrease Arrows/ allow Product Application Rate to be changed according to the Target Rate Increment. I

Strany 163 - ACCESSORIES

229 APPLICATIONLIQUID RATE CONTROLRATE CONTROL: CONTAINER LEVELWhen filling or emptying container, use the Container Level portion of the Rate Cont

Strany 164 - GPS DIAGNOSTICS

230 Firmware Version 5.2Tank AlarmsThe Container Alarm button, which appears at the bottom of the Container Level portion of the Rate screen, displ

Strany 165 - GUIDANCE

231 APPLICATIONLIQUID RATE CONTROL2. The File Selection screen appears.3. Highlight the correct .AGSETUP (prescription) or .shp (shape) file and

Strany 166 - 150 Firmware Version 5.2

232 Firmware Version 5.2SHAPE FILE CONVERSIONWhat is commonly called a shape file is actually a collection of three different files. All three of t

Strany 167 - CREATE TILLAGE CONFIGURATION

233 APPLICATIONLIQUID RATE CONTROL3. Select Data From Shape FileSelect the column that contains the product recommendation rate. The list on the r

Strany 168 - RUN CONFIGURATION

9 GENERALINSTALLATIONFUSE INSTALLATION AND REPLACEMENT Fuse Type: Blade Style (ATO/ATC)Rating:Fuse Holder (orange wire) 5A, 250 VACFuse Holder (pin

Strany 169 - Coverage

234 Firmware Version 5.2• Flow Meter Pulse Countprovides a rolling count of pulses generated from the flow meter during product application. This d

Strany 170 - 154 Firmware Version 5.2

235 APPLICATIONLIQUID RATE CONTROL4. Verify the boom offsets are appropriate for the sprayer.Problem: No “As Applied” rateSolution: 1. Check cabl

Strany 171 - CONFIGURATION

236 Firmware Version 5.22. Make sure the Outside Boundary Option is set to Turn Section Off under the Automatic Swath Control options.3. Make sure

Strany 172

237 APPLICATIONLIQUID RATE CONTROLSprayStar Rinse CycleWhen using the rinse cycle feature on the SprayStar, the display must have the boom sections

Strany 173 - CREATE PLANTING CONFIGURATION

238 Firmware Version 5.2SERVO CONTROL VALVE SETTINGS (BY MANUFACTURER)Flow Control ValveControl Valve ConfigurationValve Response 1Valve Response 2

Strany 174 - 158 Firmware Version 5.2

239 APPLICATIONLIQUID RATE CONTROLDickey-john NH3 Heat ExchangerIn-line Servo 40% 10% 8Flow Control Valve or Sprayer Model (and year if applicable)

Strany 175

240 Firmware Version 5.2Case IH 4260 with KZKCO valveNon-AIM Command Mode By-Pass Servo2% 40% 10% 5Case IH 3150 with Raven valveNon-AIM Command Mod

Strany 176 - AUTOMATIC AUTOSWATH CONTROL

241 APPLICATIONLIQUID RATE CONTROL*Adjust this number to fit your particular configuration.**If you are using a PWM control valve, some adjustment

Strany 177

242 Firmware Version 5.2LIQUID SERVO SETTINGS DESCRIPTION• Valve Response 1Default Value: 100%Determines the speed of the servo valve when product

Strany 178 - 162 Firmware Version 5.2

243 APPLICATIONLIQUID RATE CONTROL• Allowable ErrorDefault Value: 2%2% - 3% is the normal dead band setting range.- Too low of a setting value can

Strany 179 - RATE CONTROL

10 Firmware Version 5.2 An on-screen Keyboard is made available when appropriate for use during all setup processes. Press the keyboard button to a

Strany 180 - Channel Tab settings

244 Firmware Version 5.2MISCELLANEOUSGLOSSARY OF APPLICATION SETTINGSConfiguration Settings• Rate Outside of Field Rate that will be used outside o

Strany 181 - Auxiliary Tab settings

245 APPLICATIONLIQUID RATE CONTROL• Coverage OptionBased on the coverage option selected, this setting determines the behavior of the swath section

Strany 182 - PLANTERS

246 Firmware Version 5.2• Zero Flow OffsetRepresents the maximum duty cycle that is sent to the control valve without producing any hydraulic flow

Strany 183

247 APPLICATIONLIQUID RATE CONTROLFERTILIZER DEFAULT PRODUCT SETTINGS Material TypeAbbreviated name for display and predefined name for SMSPercenta

Strany 185 - Auxiliary Tab

249 APPLICATIONINJECTIONAPPLICATIONINJECTIONDirectCommand interfaces with the Raven SCS Sidekick™ for complete control over chemical injection appl

Strany 186

250 Firmware Version 5.2• Error DelayThe number of seconds that the actual rate falls out of the error threshold before an alarm sounds.Flow Monito

Strany 187

251 APPLICATIONINJECTION7. Enter Actual Dispense AmountEnter in the actual amount of the product that was dispensed. Press to continue.8. Calib

Strany 188

252 Firmware Version 5.23. Acknowledge the WarningA warning appears, stating that you must circulate the product back to the Direct Injection tank

Strany 189 - Seed Meter

253 APPLICATIONINJECTION • (A) Mapping Toolbox• (B) Product Control Toolbox• (C) Injection Controls button• (D) NORAC UC5 Boom Height Control Op

Strany 190 - CALIBRATING SEED RATE METERS

11 SETUPCONFIGURATIONSETUPSETUPCONFIGURATIONINITIAL STARTUPAn Initial Setup wizard is presented on startup.Once the wizard is completed, it is not

Strany 191 - RODUCT CONTROL TOOLBOX

254 Firmware Version 5.2Direct Injection: Pump Doesn’t RunPower can be checked at multiple locations. First is the connection at the Injection modu

Strany 192 - RATE CONTROL SETTINGS

255 APPLICATIONINJECTIONBATTERY POWER PIN OUTS Direct Injection: Pump Runs Full SpeedDigital Pump Speed Sensor - The injection pump’s digital pump

Strany 193 - LOADING PRESCRIPTIONS

256 Firmware Version 5.2ANALOG SPEED PIN OUTS Direct Injection: Application ErrorThe injection module requires that a pump calibration be performed

Strany 194 - ROUBLESHOOTING

257 APPLICATIONINJECTIONDISCHARGE FLOW SENSOR PIN OUTS Direct Injection: Inlet RestrictionThe injection pump has a vacuum switch that is used to wa

Strany 195

258 Firmware Version 5.2Rate Response Warning• Error ThresholdThe user-defined percentage of actual rate error allowed before an alarm sounds.• Err

Strany 196

259 APPLICATIONOPTRXAPPLICATIONOPTRXOptRx uses sensors, usually mounted on the sprayer’s booms, to assess reflected light to determine plant vigor.

Strany 197 - DOWN FORCE

260 Firmware Version 5.2CROP SENSOR SETUPCorn SettingsThe Crop Sensor Setup screen is where you can adjust the rate displayed on the Map screen Equ

Strany 198

261 APPLICATIONOPTRXManaged Rate - amount of nitrogen crop will uptake throughout a single season. Number of Applications - times per season N will

Strany 199

262 Firmware Version 5.2 Press: Map View button > Rate Table buttonThe display can have 2-16 ranges. Each Range is defined by a lower and upper

Strany 200 - OWN FORCE STATUS

263 APPLICATIONOPTRXRUN CONFIGURATIONOnce a configuration has been completed, the Map View button appears at the bottom of the Home screen. Press t

Strany 201 - LANTER OPTIONS SCREEN

12 Firmware Version 5.2LOCATION SPECIFIC SETUP1. Language2. Unit SystemImperial or Metric3. Date and TimeSet to GPS Time and Date requires ZDA N

Strany 202 - OWN FORCE ALARM SCREENS

264 Firmware Version 5.2Note: In order to create an accurate Reference Strip, record for at least 300 seconds (5 minutes) in Corn and North Americ

Strany 203

265 APPLICATIONOPTRXThe Crop Sensor Settings screen (A) is where you can adjust application rate settings specified by the OptRx Crop Sensor module

Strany 204 - 188 Firmware Version 5.2

266 Firmware Version 5.2• Min Rate (shown at Crop Sensor Setup)The lowest amount of N that should be applied.• NRefers to Nitrogen being applied.•

Strany 205 - SEED TUBE MONITOR MODULE

267 APPLICATIONOPTRXTROUBLESHOOTING OPTRX ERROR MESSAGESThe OptRx Crop Sensors have error messages to inform the user of complications in communica

Strany 206

268 Firmware Version 5.2

Strany 207

269 APPLICATIONNORAC UC5APPLICATIONNORAC UC5NORAC UNLOCKPress: Home button > Setup (wrench) button > Display button > Features tabThe Feat

Strany 208 - PLANTER OPTIONS

270 Firmware Version 5.2SETUP CONFIGURATIONPress: Home > Setup (wrench) button > Configuration (tractor) button > Configuration tab > (

Strany 209 - SEED MONITOR ALARMS

271 APPLICATIONNORAC UC5The following settings appear on the General Tab.Minimum Height Mode includes three selections:• Absoluteno sensors are all

Strany 210 - SEED MONITOR THRESHOLDS

272 Firmware Version 5.2RUN CONFIGURATIONOnce a configuration has been completed, the Map View button appears at the bottom of the Home screen. Pre

Strany 211

273 APPLICATIONNORAC UC5Boom Height Control Options ScreenPressing the Boom Height Control Options button (A) opens the Boom Height Control Options

Strany 212 - LEGEND SELECT

13 SETUPCONFIGURATIONSINGLE DISPLAYPress “Single Display” button then to continue.NEW SETUPPress “New Setup” button then to continue.Press to

Strany 213 - Legend Setup

274 Firmware Version 5.2

Strany 214 - DVANCED SEED MONITORING

275 APPLICATIONSPREADERAPPLICATIONSPREADERDirectCommand for spinner spreaders is capable of controlling the product conveyor, spinner speed, monito

Strany 215 - PLANTER PERFORMANCE SCREEN

276 Firmware Version 5.28. Enter Controller NameController name defaults to DirectSpreader. Press to accept, or press to enter a new name if d

Strany 216 - Row Performance screen

277 APPLICATIONSPREADEREnter Vehicle Make and Model (a suggested name appears)- If desired, press to enter a different name for your vehicle. Pre

Strany 217 - VIRTUAL SEED TRENCH

278 Firmware Version 5.2Spreader Control: PWM Control Valve• PWM FrequencyThe frequency that the PWM control valve is pulsed at. Settings can be fo

Strany 218 - 202 Firmware Version 5.2

279 APPLICATIONSPREADER- Decreasing this value will have the overall effect of speeding up servo valve response.- Increasing this value will have t

Strany 219 - KINZE PLANTER MONITOR

280 Firmware Version 5.2from the Product Selection screen of the Field Operation Wizard when starting a field operation. Press: Home button > Se

Strany 220 - Other Sensors

281 APPLICATIONSPREADER2. Enter a Base Amount of product and the controlling Units for the dry product blend. Press to continue.Note: The Base

Strany 221 - Muxbus Sensor Detection

282 Firmware Version 5.2• (A) Mapping Toolbox• (B) Product Control Toolbox• (C) Conveyor Indicator• (D) Spreader Control button• (E) AutoSwath• (F)

Strany 222 - Sensor Detection

283 APPLICATIONSPREADERSpreader Control screen• Spread WidthPress to edit the value.• Spinner SpeedThe spinner speed required for accurate product

Strany 223 - Highlight Specific

iii TABLE OF CONTENTSTable of ContentsGeneralAbout this ManualIntroduction and Company Profile ...

Strany 224 - KINZE Seed Monitor Alarms

14 Firmware Version 5.2IMPORT SETUPPress “Import Setup” button then to continue.Select desired setup file from directory. Press to accept the s

Strany 225

284 Firmware Version 5.2Conveyor rates for previously applied products can be found by first pressing the Spreader Control button which opens the S

Strany 226

285 APPLICATIONSPREADER• Feed GateChecking the Feed Gate check box enables the Feed Gate Actuator. Spreader Control: Routine OperationsThe Spreader

Strany 227 - ISPLAY ITEMS ON EQUIPMENT TAB

286 Firmware Version 5.24. Select Conveyor to CalibratePress to continue.5. Enter Dispense AmountEnter the desired target amount of product to

Strany 228 - Planter Monitor Module screen

287 APPLICATIONSPREADER3. Enter Actual WeightThe Accumulated Weight is shown in the top portion of the window. Press to enter the Actual Weight,

Strany 229

288 Firmware Version 5.2(You must make sure to account for sprocket ratios if chain driven).3. Check the user-defined value found under the control

Strany 230

289 APPLICATIONSTRIP TILLAPPLICATIONSTRIP TILLDirectCommand for Strip-Till applicators monitors bin level and fan speed sensors, maintains an accur

Strany 231

290 Firmware Version 5.27. Enter Controller NameController name defaults to DirectStrip Till. Press to accept, or press to enter a new name if

Strany 232 - 216 Firmware Version 5.2

291 APPLICATIONSTRIP TILL16. Enter Implement NameA suggested name for the implement appears. Press to accept or press to enter a name for the

Strany 233 - LIQUID RATE CONTROL

292 Firmware Version 5.22. Select ImplementSelect an implement from the drop-down list menu, or press to create a new implement. Press to conti

Strany 234 - OptRx Crop Sensor

293 APPLICATIONSTRIP TILL14. Assign Container NameContainer name defaults to “Bin 2, or 3”. Press to enter a new name if desired.15. Assign Con

Strany 235

15 SETUPCONFIGURATIONPress “First Display” button then to continue.NEW SETUPPress “New Setup” button then to continue.Press to enter a Displa

Strany 236

294 Firmware Version 5.2CONTROLLER SETTINGSPress: Home button > Setup (wrench) button > Configuration (tractor) button > Configuration tab

Strany 237

295 APPLICATIONSTRIP TILL• Max Metering SpeedSetting determines the maximum RPM of the metering shaft that controls product distribution to the app

Strany 238 - Controller Settings

296 Firmware Version 5.2• Actuator Response 1Determines the speed of the actuator when product control error exceeds the Response Threshold setting

Strany 239 - PWM Standby

297 APPLICATIONSTRIP TILL Actuator/Clutch LogicDetermines Actuator/Clutch Behavior on Zero Rate Fertilizer Blend SetupDry fertilizer blends are set

Strany 240 - .FENCE ROW NOZZLE INDICATORS

298 Firmware Version 5.25. Press to start the process of adding components to the fertilizer blend.Note: Any liquid herbicides set up within th

Strany 241

299 APPLICATIONSTRIP TILLThe Strip Till Control screen appears. Press the Prime button to access the Air Cart Prime screen.The Air Cart Prime scree

Strany 242

300 Firmware Version 5.2The Start Prime button (A) begins the meter prime routine and each meter shaft will rotate the number of revolutions as def

Strany 243 - APPLICATION

301 APPLICATIONSTRIP TILLPress the Strip-Till Control button to display the Strip-Till Control screen and settings. These settings include Product

Strany 244

302 Firmware Version 5.2Press: Map button > Strip Till Control button > Static Calibration button1. Read Static Calibration warningA warning

Strany 245 - RATE CONTROL: CONTAINER LEVEL

303 APPLICATIONSTRIP TILLStatic CFR Calibration Procedure for Ground Drive SystemsThe Static CFR Calibration Procedure performs an automated routin

Strany 246

16 Firmware Version 5.2IMPORT SETUPPress “Import Setup” button then to continue.Select desired setup file from directory.Press to accept the se

Strany 247

304 Firmware Version 5.2press the In-Field Calibration button on the Strip-Till Control screen, and the In-Field CFR Calibration Wizard appears. 1.

Strany 248 - HAPE FILE CONVERSION

305 APPLICATIONSTRIP TILLProblem: AutoSwath turns on the booms too fast or too slow. Solution: Check GPS offsets in the vehicle setup to verify a

Strany 249 - IQUID APPLICATION DIAGNOSTICS

306 Firmware Version 5.2FERTILIZER DEFAULT PRODUCT SETTINGS Material TypeAbbreviated name for display and predefined name for SMSPercentage (in ter

Strany 250

307 HARVESTHARVEST MONITORING/MAPPINGHARVESTHARVESTHARVEST MONITORING/MAPPINGDISPLAY PREPARATION• Create a backup of your spring information. Go to

Strany 251

308 Firmware Version 5.23. Input Header OffsetFor combines with offset headers, this compensates for the distance between the center of the vehicl

Strany 252

309 HARVESTHARVEST MONITORING/MAPPINGCAUTION: If Reset All is pressed the sensor will have to be calibrated for all headers!Input Header OffsetIf t

Strany 253 - CONTROL VALVE SETTINGS

310 Firmware Version 5.21. Run SeparatorStart the separator and feeder house with the proper header attached. Run at full speed.CAUTION: Do not ha

Strany 254

311 HARVESTHARVEST MONITORING/MAPPING1. Measure Moisture on Grain SamplesRandomly sample grain harvested into an active region, then measure moist

Strany 255 - Allowable Error

312 Firmware Version 5.25. Calibration Load warningRead warning, press when finished.6. Name Load Display will give load a default name of time

Strany 256

313 HARVESTHARVEST MONITORING/MAPPINGWhen performing a Harvest operation, the AutoSwath feature includes sensitivity levels, which compensate for v

Strany 257

17 SETUPCONFIGURATIONPress “Additional Display” button then to continue.Select desired setup file from directory. Press to accept the setup and

Strany 258 - Default Value: 30

314 Firmware Version 5.2 • (A) GPS Status• (B) Total Field Area• (C) Ground Speed• (D) Diagnostics button• (E) Map Legend (varieties)• (F) Legend

Strany 259 - DICKEY-JOHN NH3 CONVERSIONS

315 HARVESTHARVEST MONITORING/MAPPING- If the actual moisture is below the set dry moisture percentage and "Expand Bushels for All Grains Belo

Strany 260 - MISCELLANEOUS

316 Firmware Version 5.2MAP SCREEN: FLOW DELAYWhen the Map screen is running in a Zoom Detail view, instantaneous coverage (A) is shown automatical

Strany 261 - Auxiliary Input Settings

317 HARVESTHARVEST MONITORING/MAPPINGThe illustration at left shows how the display could track two different varieties. In this example, when the

Strany 262

318 Firmware Version 5.2• If you have selected Automatic Region Changing, a message tells you that the display has detected a different variety, an

Strany 263

319 HARVESTHARVEST MONITORING/MAPPINGPossible Cause: The reference file selected exceeded the allowable memory limit used to load reference maps.So

Strany 265 - INJECTION

321 HARVESTCLAAS QUANTIMETERHARVESTCLAAS QUANTIMETERThe CLAAS Quantimeter Optical Sensing System includes the option of interfacing with the displa

Strany 266

322 Firmware Version 5.2Note: Adjustment of Combine Settings and the Header Sensor Calibration is performed through the CLAAS CEBIS monitor.• Vehi

Strany 267 - Priming an Injection Pump

323 HARVESTCLAAS QUANTIMETERCreate a new Field Operation Configuration.After you have completed the grain weight calibration and a new calibration

Strany 268

18 Firmware Version 5.2Use the scroll bar to find the file you wish to import.When a setup file is created it is saved in a folder titled with the

Strany 269 - INJECTION DIAGNOSTICS

324 Firmware Version 5.2MAP SCREEN FOR CLAAS QUANTIMETEROnce an operating configuration is created for a CLAAS Quantimeter harvest configuration, a

Strany 270

325 HARVESTCLAAS QUANTIMETERNotes:• The Grain Harvest Diagnostics screen displays different information than the Diagnostics screen that appears fo

Strany 271 - DIGITAL PUMP SPEED PIN OUTS

326 Firmware Version 5.2Possible Cause: The display has detected that the crop type specified in the CEBIS monitor has changed to a crop type that

Strany 272 - ANALOG SPEED PIN OUTS

327 APPENDIXAPPENDIX APPENDIXSYSTEM DIAGRAMS REFERENCETo view detailed system diagrams for various machine configurations, go to the Support tab of

Strany 273 - VACUUM SWITCH PIN OUTS

328 Firmware Version 5.2LEGACY FILE FORMATSPRESCRIPTION MAP FILE TYPES• .irxThe .irx file supports multiple product recommendations in a single fil

Strany 274 - Run Screen

329 APPENDIX• .msfThe .msf (Management Setup File) file format allows the display to import Grower and Field information from SMS software via the

Strany 275 - CREATE CONFIGURATION

330 Firmware Version 5.2access to the locked-down features by unauthorized personnel and you as owner of the display agree to indemnify and hold ha

Strany 276

331 INDEXIndexAAB/smartpath toggle 125active line cycle 126adaptive curve 120area count 127heading change 127heading threshold 127new pass 127adapt

Strany 277

332 Firmware Version 5.2Ggear ratioexample 171, 173multiple drives 171, 172single motor drive 170gear ratio calculation 170GPS button 19grain harve

Strany 278

333 INDEXshift by distance 124shift by rows 124planter configurationEdgeVac 205pre-harvest preparation 307product name 26product option 26add produ

Strany 279

19 SETUPCONFIGURATIONMost of the functionality of the display is not available until the basic setup process is completed. (A) Status bar(B) Setup

Strany 280 - CROP SENSOR SETTINGS

334 Firmware Version 5.2wet weight 314Yyield 314, 315

Strany 281 - GLOSSARY OF OPTRX TERMINOLOGY

20 Firmware Version 5.2• Display buttonPress to adjust settings for Time and Date, brightness and volume settings, operating units, language; enabl

Strany 282

21 SETUPCONFIGURATIONNote: The display will then shut down immediately. If you do not want to shut the display down, press the Close (Red X) butto

Strany 283

22 Firmware Version 5.2The Display tab contains functionality for setting up a Display Owner and making any needed edits to the owner personal info

Strany 284 - 268 Firmware Version 5.2

23 SETUPCONFIGURATIONADVANCED TABPress: Home button > Setup (wrench) button > Display button > Advanced tabThe Advanced Tab allows you to

Strany 285

iv Firmware Version 5.2Display tab... 21Featur

Strany 286

24 Firmware Version 5.2- Create Backup. Press to create a backup file of all configuration settings, products, and Grower-Farm-Field Management dat

Strany 287

25 SETUPCONFIGURATION• Add buttonPress to add an operating configuration. A wizard takes you through the process of creating a configuration.• When

Strany 288

26 Firmware Version 5.2• Add or import Harvest products.• Add buttonPress to add or import a Product. At the following screen, choose a Product Opt

Strany 289 - BOOM HEIGHT DIAGNOSTICS

27 SETUPCONFIGURATION- Color Scheme- Ranges- Reset to Default LegendFor more information, see “Legend Settings” on page 55.Grain Harvest Settings•

Strany 291 - SPREADER

29 SETUPMANAGEMENT SETUPSETUPMANAGEMENT SETUPCONFIGURATION SELECTIONNote: Configuration Setup is specific to an operation (Guidance, Tillage, Plant

Strany 292

30 Firmware Version 5.2Some Modules Not Detected Configuration can be loaded but is not detecting all the modules associated with the configuration

Strany 293

31 SETUPMANAGEMENT SETUPEVENTSEvents are used to track field operations. New events can be created at anytime and therefore a physical field can be

Strany 294 - Spreader Control

32 Firmware Version 5.2Starting an EventPress Select Event button.Note: This screen does not appear when operating in Events Only mode. Enable Mana

Strany 295 - CREATING PRODUCTS

33 SETUPMANAGEMENT SETUPNext screen will vary depending on configuration.For Example:The screen shown to the left will appear for Guidance configur

Strany 296 - CREATING DRY FERTLIZER BLENDS

v TABLE OF CONTENTSSetup Event...49Field Fi

Strany 297

34 Firmware Version 5.2Select a Previous EventPress event name on Event bar.Note: This screen does not appear when operating in Events Only mode.Ma

Strany 298

35 SETUPMANAGEMENT SETUPGrowerThe Grower refers to the business or person that the system is in operation for. Contact information can also be ente

Strany 299 - Spreader Control screen

36 Firmware Version 5.2The Field Information screen opens, showing the name of that field in the Title Bar. Field Name information that can be adde

Strany 300

37 SETUPMANAGEMENT SETUPThe File Selection screen appears. Highlight the desired file to import.Operator can import/export all fields and boundarie

Strany 301

38 Firmware Version 5.2USERS TABPress: Home button > Setup (wrench) button > Management (Barn) button > User tabManagement Setup screen -

Strany 302

39 SETUPMANAGEMENT SETUP• Remove buttonPress to remove an operator.User Setup buttonPress: Home button > Setup (wrench) button > Management (

Strany 303

40 Firmware Version 5.2OpeGeneralPhone/EmailAddressOperatorManagerFull Permission LevelEdit PersonPermissionsFullPermission Levelrators• Have full

Strany 304

41 SETUPMANAGEMENT SETUP Custom PermissionCan allow or deny the following options:• Management screen• Pan/Zoom controls• Legend Toolbox• Marks

Strany 305 - STRIP TILL

42 Firmware Version 5.2Setup and USB buttons are locked for Operators if a Manager is present in the system. A Manager can access setup menu and US

Strany 306

43 SETUPMANAGEMENT SETUPACCESSING SETUP MENUS1. Press Setup (wrench) button.2. Select Manager from drop-down menu. Press .3. Enter password. Pr

Strany 307

vi Firmware Version 5.2SettingsEquipment Settings... 7

Strany 308

44 Firmware Version 5.2Password generator will require the following information:• (A) Display serial number• (B) Major revision- First digit of fi

Strany 309

45 SETUPMANAGEMENT SETUP• Remove buttonPress to remove a business.

Strany 310

46 Firmware Version 5.2

Strany 311

47 SETUPFIELD OPERATIONSSETUPFIELD OPERATIONSA. Operator Selection, see “Operator Selection” on page 47B. Edit Operator, see “User Setup button”

Strany 312 - Strip Till Control

48 Firmware Version 5.22. Choose the operator from drop-down menu.Note: Checkbox will require a password to be entered upon start up of the displa

Strany 313 - Fertilizer Blend Setup

49 SETUPFIELD OPERATIONSSETUP EVENTYou must have already created the following: • A Season, Grower, Farm and Field in Setup Management. For more in

Strany 314 - LOAD CONFIGURATION

50 Firmware Version 5.24. Return to Home screenWhen you complete the steps in the Wizard, you will return to the Home screen.• For information on

Strany 315

51 SETUPFIELD OPERATIONSRUN SCREENS • (A) Status Bar• (B) On-screen Light bar• (C) Mapping toolbox• (D) Mapping Function tabs• (E) Product Control

Strany 316 - RUN TIME OPERATIONS

52 Firmware Version 5.2Note: For more information on the Video screen, see “Video” on page 66.AutoSwath button. Pressing this button turns the Aut

Strany 317 - Strip Till Control Screen

53 SETUPFIELD OPERATIONSEngage - Not ReadyGrey with a red circle and slash if the autosteer system is off and unable to engage.Note: For more info

Strany 318 - Calibration

vii TABLE OF CONTENTSOmniSTAR Settings — GPS 2500 ...108Serial Port Settings...

Strany 319

54 Firmware Version 5.2Vehicle Icon - Zoom to ExtentThe Vehicle Icon is shown by an arrow inside a circle if the Map screen is viewed in Zoom to Ex

Strany 320

55 SETUPFIELD OPERATIONSMap Legend tabPress the Map Legend button at the top of the Mapping Toolbox, and the Legend appears, either for Rate or Cov

Strany 321

56 Firmware Version 5.2Notes:• The Legend Settings screen can also be accessed by pressing the Edit Legend button on the Setup screen’s Product Tab

Strany 322

57 SETUPFIELD OPERATIONSMarkers tabMarkers are a collection of point objects that are available on the Map Markers tab of the Mapping Toolbox. Map

Strany 323 - HARVEST MONITORING/MAPPING

58 Firmware Version 5.2BoundaryPress the Boundary button on the Field tab to access the Boundary Options screen. On the Boundary Options screen, y

Strany 324

59 SETUPFIELD OPERATIONS2. If you chose to create an Inner Boundary, use the Region Type drop-down menu to choose the type of boundary. Choices in

Strany 325

60 Firmware Version 5.2Active Area Work Area Headlands AllAdd a HeadlandPress on Headlands Options screen.Select Headland T

Strany 326 - MOISTURE CALIBRATION

61 SETUPFIELD OPERATIONSDriven1. Select Driven from drop-down menu and press to continue.2. Press on New Headlands screen.3. Input Headland O

Strany 327 - New Load

62 Firmware Version 5.2Edit HeadlandsPress Edit Headlands button. Select a headland from list.• Press to add a driven headland.• Press to delet

Strany 328 - Load Name

63 SETUPFIELD OPERATIONSTopographyThe display allows you to record points that can be used to make a reference layer that is relative to the elevat

Strany 329

viii Firmware Version 5.2Remove Pattern/Remove All Patterns... 129Reset Pattern...

Strany 330 - HARVEST STATUS ITEMS

64 Firmware Version 5.2If you have RTK GPS reception, you are allowed to collect an elevation survey. This will allow you to collect the Lat/Long a

Strany 331 - MAP OPTIONS

65 SETUPFIELD OPERATIONSAfter these points have been collected, they will be converted into a surface layer in which you can define the color schem

Strany 332 - MAP SCREEN: FLOW DELAY

66 Firmware Version 5.2In Odd-shaped fields, the surface rendering of the elevation will connect areas (A) even if you haven’t driven through that

Strany 333 - HARVEST

67 SETUPREPORTSSETUPREPORTSSUMMARY REPORTPress: Home button > Summary buttonThis screen shows you field totals and averages. Use the drop-down m

Strany 334 - IMPORTING VARIETY MAPS

68 Firmware Version 5.2• Crop Residue Level• Soil Condition• Soil Moisture• Soil TemperaturePress: Home button > Field Notes button > Memo bu

Strany 335 - GRAIN HARVEST DIAGNOSTICS

69 SETUPREPORTS1. The Create Report screen appears, which lists the Grower, Field, and Product at top. Two drop-down menus list your Operating Con

Strany 336 - 320 Firmware Version 5.2

70 Firmware Version 5.2CONTROL CHANNEL REPORT CONTENTThe content of all product application reports is divided into two distinct groups. The first

Strany 337 - CLAAS QUANTIMETER

71 SETUPREPORTSControl Channel Content includes the following:• Service Provider Information• Grower Information• Field Information• Farm Name and

Strany 338

72 Firmware Version 5.2

Strany 339

73 SETUPEXTERNAL DRIVESETUPEXTERNAL DRIVEEXTERNAL STORAGE OPERATIONSThe External Storage Operations button is where you can copy your field data; u

Strany 340

ix TABLE OF CONTENTSConfiguration Setup...151Load Configu

Strany 341

74 Firmware Version 5.2• Marker Sets and MarkersNote: Do not use the IBK to “clone” a display. Use AGSETUP..AGDATA• Includes all the necessary dat

Strany 342 - “Bridge Module” on page 325)

75 SETUPEXTERNAL DRIVE• Equipment Used• Products Used• Marks Logged• Boundaries• Guidance Patterns• Flexible export options• Will be able to export

Strany 343 - APPENDIX

76 Firmware Version 5.2

Strany 344 - LEGACY FILE FORMATS

77 SETUPDEVICESSETUPDEVICESDEVICE INFORMATIONPressing on the Device Information button, located in the upper right corner of the display, opens the

Strany 345 - UNAUTHORIZED ACCESS

78 Firmware Version 5.2

Strany 346 - SERVICE AND SUPPORT

79 SETUPSETTINGSSETUPSETTINGSEQUIPMENT SETTINGS Press the Configuration Settings button on the Configuration Setup screen to view or edit the name

Strany 347

80 Firmware Version 5.2Equipment Configuration Settings for Rate ControlIf you are using an operating configuration with Rate Control, (such as for

Strany 348 - 332 Firmware Version 5.2

81 SETUPSETTINGSThe Speed Input Settings screen is where you can calibrate the ground speed input for accurate speed and area calculations.In most

Strany 349

82 Firmware Version 5.2Press: Home button > Setup (wrench) button > Configuration (tractor) button > Configuration tab > your specific

Strany 350 - 334 Firmware Version 5.2

83 SETUPSETTINGS• Reset All. This button resets the settings to defaults.AUXILIARY INPUT SETTINGSPress: Home button > Setup (wrench) button >

Komentáře k této Příručce

Žádné komentáře